Source-backed identification · Materials

Gasket conductivity vs whole-door heat loss

Separate individual material thermal conductivity from assembly U-factor and building heat-loss estimates. See the evidence checklist and fit limits.

A gasket's thermal conductivity and an installed door's U-factor are different kinds of evidence. Schlegel advertises 0.04 W/(m·K) at 0 °C for its Q-LON timber window/door seal range. That is the manufacturer's bounded material/range statement, not an independently established whole-door energy rating for a particular assembly.

Read the number together with its unit and test scope

Schlegel's statement is a thermal-conductivity figure associated with a seal range. DOE describes U-factor as thermal transmittance of fenestration products and identifies it, together with solar heat gain coefficient, as a major product energy-efficiency metric. The values answer different questions and cannot be equated by dropping their units.

The National Fenestration Rating Council explains that its U-factor is a rated performance characteristic of a window or door product, and it presents a distinct door-label explanation. The label is about the product rating, not simply the material name of one gasket.

Evidence you have Correctly scoped question Unsupported shortcut
Seal maker's W/(m·K) number What conductivity figure does this seal supplier advertise at the stated condition? 'My whole door has this U-factor'
NFRC door product label What certified rating applies to the identified product/configuration? 'Any door with this gasket gets the same rating'
Air movement felt around sash or frame Where should air leakage be checked? 'A single conductivity number proves the leak is fixed'

DOE separately emphasizes drafts and low air-leakage rates in product selection guidance; a U-factor alone is not a substitute for locating an air gap.

A three-record worksheet

Record (1) the exact seal SKU and its document/condition, (2) the door model and glass configuration if supplied, and (3) any actual NFRC door rating or test report tied to that assembled product. If only a generic manufacturer seal page is available, mark the installed door rating unknown. If only the door label exists, do not reverse-engineer a gasket conductivity from it.

Do not calculate projected utility savings from the advertised 0.04 number; neither an assembly model nor a verified leakage-change measurement is established by the cited seal page. For an energy-selection decision, request the actual product label or appropriate assessment, not an invented conversion between W/(m·K) and a whole-door U-factor.

Sources and references