Source-backed identification · Therma Tru

Therma-Tru: leak beneath sill or past door sweep?

Route observations to subfloor/sill perimeter versus door-bottom sweep pathway without declaring a diagnosis. See the evidence checklist and fit limits.

Short answer. Water visible near a Therma-Tru sill does not by itself identify a failed door sweep. The 2017 manufacturer water-leak table separately lists the sill/subfloor sealant, sill-to-jamb joint, damaged weatherstrip, distorted sill, saddle/bulb condition and damaged door bottom as possible causes. source The practical first task is locating where moisture first appears, without assigning a cause by guesswork.

Three observation zones, not three diagnoses

First observed moisture Record it as Candidate the document prompts you to consider
At or beneath the stationary threshold Under-sill region The manual includes insufficient/broken-down sealant between sill and subfloor. source
At the jamb-to-sill meeting point Sill/jamb corner A broken joint seal is another independent row. source
At the moving door-bottom interface Door-bottom/contact region The manual also lists damaged door bottom or sill distortion and damaged saddle/bulb contact. source

These locations help organize photographs; they cannot prove the actual concealed path. The same table includes damaged or painted weatherstrip as a separate candidate. source

A non-destructive leak log

  1. On discovering moisture, avoid exposing electrical fixtures or continuing use where water may create a hazard. Keep a dated note of rain or washing conditions rather than reproducing a damaging water test.
  2. Record the first visible wet edge before wiping it; include a wide frame photograph for orientation. If the area is already dry, write “source not observed.”
  3. Photograph both threshold ends, the entire door bottom, and the jamb weatherstrip. Show any distortion without manipulating the sill.
  4. Keep a two-column list: observed (location, time, condition) and possible (which 2017 table row might apply). Do not merge the columns.
  5. Escalate damp structural material, recurring ingress or an unlocated source for a qualified inspection rather than applying a blanket adhesive or replacing a sweep first.

How to interpret the result

Under-sill or joint evidence: prioritize inspection of original sill sealing/installation details. Visible bottom or saddle damage: investigate the matching door-bottom or adjustable-threshold assembly. No unique clue: keep all candidate routes open. The 2017 table offers different repair references, not an exact proof test or a promise that any one change makes an assembly watertight.

Primary sources and claim locator register

  • — Therma-Tru original, 2017 Site Manual — SITE 4, US; p.4.4, sill/subfloor sealant. Publisher document.
  • — Therma-Tru original, 2017 Site Manual — SITE 4, US; p.4.4, sill/jamb broken joint. Publisher document.
  • — Therma-Tru original, 2017 Site Manual — SITE 4, US; p.4.4, damaged/painted weatherstrip. Publisher document.
  • — Therma-Tru original, 2017 Site Manual — SITE 4, US; p.4.4, depressed/humped sill beyond sealing capacity. Publisher document.
  • — Therma-Tru original, 2017 Site Manual — SITE 4, US; p.4.4, damaged saddle and wrinkled bulb. Publisher document.
  • — Therma-Tru original, 2017 Site Manual — SITE 4, US; p.4.5, damaged door bottom. Publisher document.

Evidence and safety boundary

In Therma-Tru’s 2017 SITE 4 manual (printed p. 4.4), leakage near a door sill may involve the below-sill joint rather than only the door-bottom seal. Note whether moisture appears beneath the threshold, at a corner joint, or along the moving bottom edge; avoid diagnosing from a wet floor alone. Document the assembly and ask the installer or manufacturer for the appropriate inspection path before buying a sweep.