Reference guide · Compare profile shape, mounting interface and measurements · Confirm fit before ordering.
Manufacturer-catalog code reference · Offline staging

Schlegel Q-LON profile codes: groove and gap measurement reference

Look up exact Schlegel Q-LON profile codes and 15 maker-listed historical printed-code identities in one place. The contemporary code section provides approved catalog measurement fields; the historical section helps interpret old Aquamac labels without claiming that a replacement will fit.

Important distinction: Schlegel publishes historical Aquamac-to-Q-LON code references. That printed-name cross-reference is not installation-fit, physical equivalence, cross-manufacturer interchange or supersession evidence. Do not use a code conversion alone to order a seal.

Contemporary Q-LON profile rows (manufacturer PDF, mm)

Q-LON printed codeManufacturer contextMount familyThroat / seal width (mm)Minimum depth / height (mm)Source seal gap (mm)
QL 3106Q-LON maker range; see PDFmanufacturer grouped range6.53.0..5.0
QL 3110Q-LON interior design / timber doors furnituregroove / kerf-insertion3.5..4.06.53.5..4.0
QL 3113Q-LON interior design / timber doors furnituregroove / kerf-insertion3.5..4.07.04.0..7.5
QL 3138Q-LON interior design / timber doors furnituregroove / kerf-insertion2.7..3.26.03.0..4.5
QL 70014Q-LON interior design / timber doors furnituregroove / kerf-insertion4.07.04.1..7.0
QL 3063Q-LON timber windows / Centre sealgroove / kerf-insertion4.0..5.07.55.5..7.5
QL 3067Q-LON timber windows / Centre sealgroove / kerf-insertion4.0..5.07.54.0..6.0
QL 3068Q-LON timber windows / Centre sealgroove / kerf-insertion3.4..4.26.54.5..6.5
QL 3076Q-LON timber windows / Centre sealgroove / kerf-insertion3.0..3.56.03.0..6.0
QL 3025Q-LON timber windows / Frame sealgroove / kerf-insertion2.7..3.06.03.0..5.0
QL 3116Q-LON universal surface fitting / Tapedsurface-fit / taped10.88.73.0..5.5
QL 3117Q-LON universal surface fitting / Tapedsurface-fit / taped11.26.53.0..5.5
QL 3121Q-LON universal surface fitting / Tapedsurface-fit / taped15.012.05.0..10.0
QL 3122Q-LON universal surface fitting / Tapedsurface-fit / taped7.02.20.5..2.0
QL 3124Q-LON universal surface fitting / Tapedsurface-fit / taped6.43.72.5..3.5
QL 3126Q-LON universal surface fitting / Tapedsurface-fit / taped10.03.01.0..2.5

Dimension and mount context: Schlegel Q-LON manufacturer PDF (tables and illustrations). Compare manufacturer diagrams as well as numeric ranges, and record which application category the source assigns.

Historical Aquamac / Q-LON printed-code lookup (maker conversion table)

Have an older Aquamac name on a removed weatherseal, or the historical QL 5878, QL 836 or QL 9111 label? Find that exact printed code below and read the name listed alongside it in Schlegel’s official maker conversion table. Schlegel identifies Aquamac as a historical Q-LON product name; this is a code-label cross-reference only, not proof that two physical profiles are dimensionally identical or interchangeable in an existing frame.

Q-LON maker-table codeHistorical printed Aquamac code
QL 3009Aquamac 21
QL 3012Aquamac 33
QL 3013Aquamac 48
QL 3005Aquamac 63
QL 3004Aquamac 99
QL 3011Aquamac 109
QL 3015Aquamac 122
QL 3020Aquamac 124
QL 5878Aquamac 5878
QL 3006Aquamac 89
QL 836Aquamac 836
QL 9111Aquamac 9111

Source and uncertainty: Schlegel official Aquamac and Q-LON product-code conversion table, section “Q-LON and obsolete Aquamac product codes” (checked 10 October 2026). Schlegel lists QL 3015 alongside Aquamac 122 and also calls QL 3015 “Zerogap”; that is a printed-code identification note, not a verified installation-fit or part-number supersession.

Next step for each code: Photograph the old seal with the printing legible, capture the end-on profile and retaining foot, measure the channel opening, insertion depth and closing gap, then compare the exact profile drawing and your window/door maker’s applicable replacement documentation. If any geometry or OEM application is uncertain, stop rather than ordering on a code match alone. For general definitions and code history, see the weatherstrip terminology guide.

How to compare a removed sample

  1. Photograph the relaxed seal end-on with a ruler and orientation marker.
  2. Measure the actual retaining stem or backing and its receiver opening independently.
  3. Measure relaxed reach, bulb/body diameter or height and the closed-door gap without stretching or crushing the sample.
  4. Compare only the matching published fields and units; a similar profile or printed code does not establish fit.
  5. For replacement confirmation, use the exact door/window maker, model, configuration and primary part drawing.

Stop rule: Catalog dimensions and historical printed-code references are identification clues only. Do not infer OEM fit, universal interchange, current inventory, or a replacement/supersession from these pages.

Start with generic kerf-in foam-clad identification or surface-backed profile identification, depending on the actual mount—not simply on the code string.